| Max. press capacity |
(MT): |
200-5000 |
| Press force |
(kN): |
|
| Accuracy of set point |
(%): |
<3% |
| Overload protection |
(Y/N): |
Y |
| Max. size panel to be pressed |
(mm x mm x mm): |
as per req. |
| Surface pressure at panel dimensions |
(N/mm2): |
33 |
| Max. surface pressure on smaller surface in
center |
(N/mm2); |
50 |
| Dimensions heating plates (platen) |
(mm x mm): |
about 850 x 850 |
| Platen finishing |
|
64 RMS (1.6 µm) |
| Flatness over entire platen |
(mm): |
<0.1 (possible?) |
| Parallelism over entire platen |
(mm): |
<0.2 (possible?) |
| Max. deflection moving bolster (at max.
pressure) |
(mm): |
0.05 |
| Max. deflection fixed bolster |
(mm): |
0.05 |
| Table height above floor level |
(mm): |
minimum |
| Up-stroking / down-stroking (up-stroking
preferred) |
|
not specified |
| Floor / pit mounted |
|
preferably floor mounted |
| Stroke length |
(mm): |
not specified |
| Shut height (clearance over bed with ram
fully closed) |
(mm): |
0 (fully closed) |
| Daylight (vertical clearance between bolster
and ram platens) |
(mm): |
about 500 |
| Accuracy travel distance measurement |
(mm): |
none |
| Diameter of cylinder with 2 nos. Auxiliary
cylinder |
(mm): |
Ø 900main /Ø110x2 |
| Approach speed (apply pressure within 1
minute) |
(mm/s): |
10 ~ 15 (100mm/sec) |
| Pressing speed |
(mm/s): |
0.5 ~ 1 (2.5mm/sec) |
| Return speed |
(mm/s): |
10 ~ 15 (85mm/sec) |
| Type hydraulic pump |
|
Van/piston |
| Capacity hydraulic pump |
(dm3/min): |
95 LPM |
| Max. pressure hydraulic system |
(bar): |
270 |
| Tank content hydraulic oil |
(Ltrs): |
1300+1000 Pre filled |
| HE in hydraulic loop |
(Y/N): |
Y |
| Heating medium |
|
thermal oil |
| Inlet temperature heating medium |
(ºC): |
170 max |
| Max. temperature heating plates |
(ºC): |
165 |
| Temperature tolerance |
(+/-ºC): |
2 |
| Temperature uniformity |
(+/-ºC): |
2 |
| Heating up time from ambient (20ºC) to
130ºC |
(min): |
15 max |
| Heating medium required / capacity pump |
(kg/s): |
thru Boiler |
| System content thermal oil |
(l): |
depend on mould |
| Cooling medium supplied to HE to cool down
thermal oil |
|
water (30ºC) |
| Cooling platen direct / indirect (sec.
thermal oil loop cooled by water) |
|
indirect |
| Inlet temperature cooling medium |
(ºC): |
will vary according to cycle requirement
|
| Cooling down time from 130ºC to 50ºC |
(min): |
10 max |
| Cooling medium required / capacity pump
(kg/s): |
off line system |
2HP/40LPM |
| System content cooling medium* |
(l): |
thru cooling tower |
| Compressed air requirement |
(Nm3/h): |
not required |